Sale!

EXIDE STAR 700VA SINEWAVE + INVA MASTER 1000 BATTERY

Original price was: ₹16,500.Current price is: ₹16,100.

Use pincode to check delivery info

Product Description

Why Tubular Batteries are most suitable in Inverter Application?
A tubular battery uses technology that seals the active material in polyester tubes called gauntlets, instead of pasting it on the surface of the plate. As a result, there’s no shedding or corrosion, ensuring long battery life. Owing to their toughness and durability, tubular batteries can operate at extreme temperatures, and are used in high cyclic applications involving frequent and prolonged power outages.

The Exide Torr Tubular Advantage
All tubular batteries behave similarly to start with, but obviously, not all tubular batteries are the same. The difference lies in the composition of the alloy in the positive support structure, as well as in the way that the main back bone of the plates, called the SPINE, is cast.

With the help of Torr Tubular technology, Exide tubular batteries use the high pressure ‘HADI’ casting process at 100 bar, while most other manufacturers use gravity of low pressure casting processes. The spines in Exide tubular batteries are cast from low antimony lead alloy, with selenium, copper, tin, and arsenic, to protect the lead support from anodic corrosion.

A scanning electron microscope (SEM) study reveals the differences in machines that use gravity or low pressure casting, and those that are ‘HADI’ casting.

Technical Specifications of Exide Inverterz Star

Description STAR 12V 650VA STAR 12V 850VA STAR 12V 1050VA STAR 24V 1450VA
Output Voltage at No Load 220V ± 7V AC
Output Frequency 50Hz ± 1Hz
Output Wave Form Pure Sine Wave
Nominal Battery Voltage 12V DC 24V DC
Battery Low Cut Off 10.5V ± 0.2V DC 21.0V ± 0.4V DC

Charging Mode

Model STAR 12V 650VA STAR 12V 850VA STAR 12V 1050VA STAR 24V 1450VA
Maximum Charging Current (NC) 11Amps ± 1Amp 12Amp ± 1Amp 13Amp ± 1Amp 12Amp ± 1Amp
Maximum Charging Current (HC) 15Amps ± 1Amp 17Amp ± 1Amp 18Amp ± 1Amp 17Amp ± 1Amp
Boost Charging Voltage 14.4V ± 0.2V DC 28.8V ± 0.4V DC
Trickle Charging Voltage 13.7V ± 0.2V DC 27.4V ± 0.4V DC
Charging Current at 120V Mains Input 8-10 Amp Charging Current*
Charging Over Time Mains to Back-up (@ UPS Mode) ? 10 msec
Charging Over Time Back-up to Mains (@ UPS Mode) ? 10 msec
Input Voltage Range (@ UPS Mode) 180V – 270V ± 10V AC
Change Over Time Mains to Back-up (@ Normal Mode) ? 40 msec
Change Over Time Back-up to Mains (@ Normal Mode) ? 10 msec
Input Voltage Range (@ Normal Mode) 90V – 300V ± 10V AC